Back to products list
NV-PW240-48
Industrial DIN Power Supply

NV-PW240-48

Industrial DIN-Rail Power Supply (240W, 48V-57V) – NV-PW240-48 Key Features: • Optimized for industrial network devices with a continuous 48V-57V DC output. • High power output of 240W, dedicated to powering heavily loaded PoE switches. • Convenient and universal mounting on a standard industrial DIN rail. • Comprehensive protection system: short-circuit, overload, over-voltage, and over-temperature. The NV-PW240-48 industrial power supply is the absolute heart of a stable and secure infrastructure. Specifically constructed for integration into control cabinets on a DIN rail, it delivers the clean and reliable voltage required by industrial network switches and PoE-powered equipment. With a high power budget of 240W, this power supply can easily support an entire matrix of receiving devices, such as high power-consumption professional CCTV cameras (including PTZ models). The solid metal casing provides fanless heat dissipation, ensuring quiet, continuous, and 100% trouble-free operation, even in extremely harsh environmental conditions.

Key Features

Power Supply 100-240V AC
Power Consumption 240W (48V / 5A)
Enclosure Desktop

Technical Specifications

Model EW-DR-240W-48
DC Output Voltage, Current 48V, 0-5A
Rate Power (max) 240W
Wave And Noise 150mVp-p
Inlet Wire Stability ±0.5%
Load Stability ±1%
Adjustable Range For DC Voltage ±10%
Output Start Time < 25ms @ nominal input (100% load)
Output Hold Time > 20ms @ 115Vac, > 115 ms @ 230Vac (100% load)
Input Voltage Range 85~264VAC / 120~370VDC
Frequency Range 47~63Hz
Efficiency ≥89%
Input Current < 4.40A @ 115Vac, < 2.20A @ 230Vac
Inrush Starting Current < 35A @ 115Vac & 230Vac
Power Factor > 0.99 @ 115Vac, > 0.93 @ 230Vac
Over Power Protection 288-360W. Protection mode: Hiccup mode, Self-recovery after over-power released.
Over Voltage Protection 57-70V. Hiccup mode. Output recovery to normal after voltage.
Over Current Protection 6-7.5A. Protection mode: Hiccup mode, Self-recovery after over-current released.
Short Circuit Protection It achieves the long-term short circuit by connecting a sufficient cross-sectional area copper cable (Length at 15cm±5cm) with power output port. Self-recovery to normal after removing the short circuit.
Overload Protection 105%~150% cut off the output, automatic recovery.
Other voltage protection 120%~140% shut down O/P voltage, re-power on to recover.
Operation Temperature and Humidity -30°C~85°C; 20%~95%RH non-condensing.
Storage Temperature and Humidity -40°C~85°C; 10%~95%RH non-condensing.
Vibration Frequency range: 10-500Hz; Acceleration: 2G; Each sweep cycle 10min; Six sweeps along the X, Y, and Z axis.
Surge (Shock) Acceleration: 20G; Duration time: 11mS; Three shocks along X, Y and Z axis.
Altitude 2000m
Dimension 45 x 113 x 124 mm
Weight 1.2KG
Setup, rise, hold up time 1500ms, 100ms / 230VAC at full load.
Withstand voltage I/P-O/P: 1.5kV I/P-FG: 1.5kV O/P-FG: 0.5kV 1minute.
Isolation resistance I/P-O/P, I/P-FG, O/P-FG: 500VDC/100MΩ.
Smart flow control -10°C~+50°C
Terminal Pin No. Assignment (TB1) 1: FGO
2: AC/N Or DC -
3: AC/L Or DC +
Terminal Pin No. Assignment (TB2) 1,2: DC OUTPUT -V
3,4: DC OUTPUT +V